The main product of Labfer Ltd is the low-cost high-efficiency elements for nonlinear-optical laser wavelength conversion based on lithium niobate crystals, including MgO-doped ones, with regular domain structure (PPMgOLN and PPLN), as well as MgO-doped lithium tantalate crystals (PPMgOLT).

The most important features of such wavelength conversion elements are:

  • High efficiency (compared to materials using ordinary phase matching) due to utilization of the maximum value of the d33 nonlinear coefficient (for lithium niobate — up to 25 pm/V).
  • Absence of walk-off of the converted radiation.
  • High versatility — almost any nonlinear conversion can be realized, including harmonic generation, sum- or difference-frequency generation, and optical parametric oscillation.
  • Increased optical damage threshold due to suppression of photorefraction by MgO doping.
  • Comparatively low working temperature at customer's choice (usually 30–50°C).

PPMgOLN, PPCLN and PPMgO:LT crystals are manufactured by proprietary technology.

PPMgOLN, PPLN and PPMgOLT specifications

Main materials

  • MgO-doped congruent lithium niobate
  • MgO-doped congruent lithium tantalate
  • Congruent lithium niobate

Crystal dimensions

  • Length: 0.3 — 50 mm
  • Width: 1 — 50 mm
  • Thickness: 0.5 — 3 mm

Domain structures

  • Period: 4 — 30 μm(*)
  • Manufactured to customer order

Main applications

1) Second harmonic generation

Second harmonic generation scheme: red pump through a PPMgO:LN crystal, green and red output
  • Typical conversions: 1064→532 nm, 1178→589 nm, 1080→540 nm, 1246→623 nm, 1550→775 nm
  • Phase-matching temperature: from 30 to 80°C (at customer's choice)
  • Working wavelength tuning:
    • in a narrow range: by temperature
    • in a wide range: by translating a crystal with fan-out regular domain structure
  • Maximum output power of the second harmonic radiation:
    • for PPMgOLN: up to 2 W
    • for PPMgOLT: up to 12 W
  • Conversion efficiency(**):
    • CW pumping: 1.2 %/W
    • pulsed pumping: 60–70%

2) Optical parametric oscillation

Optical parametric oscillation scheme: blue pump through a crystal in a resonator, tunable signal and idler output
  • Typical pump laser wavelength: 1064 nm, 1053 nm
  • Output wavelength range (signal and idler): from 1.1 to 4.5 μm
  • Phase-matching temperature: from 30 to 80°C (at customer's choice)
  • Output wavelength tuning:
  • Maximum pulse energy of the converted radiation (signal + idler): up to 500 mJ

Machining

  • Input and output faces polished to optical quality

Antireflection coatings

  • Antireflection (AR) coatings at two wavelengths (pump and second harmonic) for second harmonic generation
  • Coatings at three wavelengths (pump, signal and idler) for optical parametric oscillation

(*) Crystals with domain period above 30 μm can be manufactured on request. For crystals thicker than 1 mm the minimum period is 15 μm.

(**) The conversion efficiency depends on the crystal length and pump laser parameters. For more accurate information on the conversion efficiency expected for your task, please contact us.

Did not find a ready solution? We manufacture crystals with custom dimensions, domain period, wavelength and working temperature for your specific task.

Labfer Ltd also produces accessories for crystals. Please contact us to clarify your order:

+7 (912) 613-48-34, sales@labfer.ru